P3754 - Concrete Inserts-Heavy Duty

0
0 review(s) | Add your review

Closure strip P3712 P and a styrene bead end cap that fits inside the channel to inhibit concrete seepage are included.

The recommended design load when used for curtain wall anchorage is 5,000 pounds and is based on use in average, good concrete. The design load includes 1â/3 increase in load as permitted by AISI Specifications and Uniform Building Code when stresses are produced by wind or earthquake and other loads.

The recommended design load is based on using two P1010 nuts at no less than 3" O.C. and no closer than 2" to either end of the insert. The distance between the insert centerline and the concrete edge must be a minimum of 3".

All nuts and fittings for P3200 series concrete inserts will fit.

Material: Cold formed from 12 Ga. (2.7mm) steel conforming to ASTM A1011 SS GR 33 or ASTM A653 GR 33 A. Stainless steel available on special order.

Finish: Choice of Perma-Green II (GR), hot-dipped galvanized (HG) conforming to ASTM A123 or A153, pre-galvanized (PG) conforming to ASTM A653-G90, or plain (PL).

Safety factor - 3

Material:

  • Cold-formed inserts are manufactured from standard 12 gauge (2.7 mm) Unistrut channel sections conforming to ASTM A1011 SS GR 33 or ASTM A653 GR 33, unless otherwise noted.
  • Hot-rolled inserts, as noted, are manufactured from carbon steel meeting physical requirements of ASTM A283 GR D.
  • To inhibit concrete, all inserts (except spot inserts) are provided with closure strips and end caps or foam filler, unless otherwise requested.
  • Most concrete inserts are available in stainless steel on special order. Consult factory for ordering information.

Application:

  • A wide range of heavy-duty to light-duty “continuous” and “spot” concrete inserts are available for use in pre-cast, pre-stressed or poured-in-place concrete floors, walls or ceilings.

Dimensions:

  • Imperial dimensions are illustrated in inches. Metric dimensions are shown in parenthesis or as noted. Unless noted, all metric dimensions are in millimeters.
    Custom-designed inserts are available on special order. Consult factory for ordering information.

Design Load:

  • Design loads, where shown, are based on 3,000 PSI concrete, unless noted.

Standard Lengths:

  • Insert lengths range from 3 inches (76 mm) to 20 feet (6.10m) with a tolerance of ±1/4-inch (6.4mm).

More than 200 pages to explore

Unistrut metal framing channel, fasteners and hardware are the materials of choice for OEMs, contractors and plant maintenance personnel. Download the catalog to learn more.

1.jpg